FN Series Cold Room Use Air Cooled Condenser For Refrigeration System
Condenser Description :
FN seroes air - cooled condenser is a kind of special in the open air , semi - closed and totally enclosed compressor condenser . Heat disspation area by 3 , 1380 ㎡ . FN type air cooling condenser FNH and FNV two series . FNH with horizontal air supply type , FNV for vertical air supply type ; FNH model suitable for small and medium - sized close partly or fully enclosed compressor , FNV type is suitable for large amount of cold compressor . FNV type is suitable for large amount of cold compressor . Condenser separately installed on the out outside , and the compressor piping connections between in lieu of water cooled condenser .
Products Feature :
Technical Parameters :
Technical parameters of industrial condensers | ||||||||||||||
Model |
Heat - exchange △t = 15kw |
Heat- exchange area |
fan | Diameter of inlet tube | Diameter of outlet tube | Dimensions | Mounting dimensions | |||||||
Quantity | Diameter of fan | Air volume | Power | Voltage | ||||||||||
W | m2 | N | φmm | m3/h | W | V | Φ mm | Φ mm | L | B | H | D | E | |
FNV - 26 / 72 | 25890 | 72 | 1 | 4D550 | 8487 | 600 | 380 | 22 | 16 | 950 | 900 | 880 | 870 | 700 |
FNV - 31 / 87 | 31320 | 87 | 1 | 4D600 | 10820 | 780 | 380 | 25 | 16 | 1100 | 1000 | 880 | 1020 | 700 |
FNV - 40 / 110 | 39800 | 110 | 2 | 4D500 | 2×6246 | 2×450 | 380 | 25 | 16 | 1400 | 900 | 880 | 1320 | 700 |
FNV - 47 / 130 | 46800 | 130 | 2 | 4D550 | 2×8487 | 2×600 | 380 | 28 | 19 | 1550 | 900 | 880 | 1470 | 700 |
FNV - 56 / 155 | 55800 | 155 | 2 | 4D500 | 2×8487 | 2×600 | 380 | 28 | 19 | 1600 | 1000 | 980 | 1520 | 800 |
FNV - 67 / 185 | 66700 | 185 | 2 | 4D600 | 2×12500 | 2×780 | 380 | 28 | 22 | 1700 | 1000 | 1080 | 1620 | 800 |
FNV - 76 / 210 | 75680 | 210 | 2 | 4D630 | 2×13000 | 2×800 | 380 | 32 | 22 | 1750 | 1000 | 1180 | 1670 | 800 |
FNV - 86 / 240 | 86420 | 240 | 2 | φ700 | 2×15000 | 2×750 | 380 | 32 | 22 | 1900 | 1175 | 1260 | 1820 | 975 |
FNV - 108 / 300 | 10800 | 300 | 2 | φ750 | 2×19000 | 2×1100 | 380 | 35 | 25 | 2250 | 1175 | 1260 | 2170 | 975 |
FNV - 115 / 320 | 11520 | 320 | 2 | φ750 | 2×19000 | 2×1100 | 380 | 38 | 25 | 2350 | 1175 | 1260 | 2270 | 975 |
FNV - 130 / 360 | 129600 | 360 | 3 | φ650 | 3×13200 | 3×550 | 380 | 42 | 28 | 2650 | 1175 | 1260 | 2570 | 975 |
FNV - 144 / 400 | 144000 | 400 | 3 | φ700 | 3×15000 | 3×750 | 380 | 42 | 28 | 2950 | 1175 | 1260 | 2870 | 975 |
FNV - 173 / 480 | 172800 | 480 | 3 | φ750 | 3×19000 | 3×1100 | 380 | 54 | 28 | 3400 | 1175 | 1260 | 3320 | 975 |
Note : four - pole external rotor fans shall be used for the heat - exchange area less than 210 ㎡ . And six - pole axial flow fans shall be used for the heat - exchange area more than 240 ㎡ .